Nordyne Blower Motor Control Module - HVAC-Talk
Jul 1, 2020 · It has a variable speed blower motor made by Broad-Ocean. I determined that the Thermistor burned out in the Control Module on the back of the blower motor. Does anyone know where I can just get a Control Module? Or a Thermistor? The Thermistor is an NTC 1D-25. The blower motor is a Broad-Ocean Motor # ZWK763D00501 (622448).
Carrier Variable Speed Fan Motor/Module - HVAC-Talk
Nov 9, 2020 · Hi All, Just bought two year old house with a couple of Carrier Infinity HP systems - so, sadly not the original owner. Code 41-Blower Motor Fault and 44-Fan Coil Cannot Communicate with Blower. Air handler unit Model is FE 4ANF003. From my reading it is better than 50% chance of module failure, vice motor itself, but won't know till it is open.
Blown ECM motor replaced and new motor not working - HVAC-Talk
Dec 21, 2023 · I threw in the towel and called a HVAC tech. He tested the module and motor, Etc. I was entrusted to pull and reinstall the power plug. While he was wiggling wires, I saw a spark, He investigated and a black wire had pulled off a spade connector. Vroom went blower! The call was ***, The fix was ***, and my Ebay motor was ****. For about **** total.
How to buy replacement genteq ECM 3.0 blower motor - HVAC-Talk
Oct 10, 2015 · My blower quit working and the circuit board says it is a motor problem. I have a carrier infinity model FE4ANF003T00ABAA SER. NO. 2910A70022. The ECM module is 5SME39HXL3006A CUSTOMER NO. HD44RE122. The motor has resistance and will generate current so I may just need the ECM module, which is an ECM 3.0 GC08.
Carrier 58MVP Blower motor Lockout Code 44 - HVAC-Talk
Mar 30, 2007 · Code 44 set (Blower motor lockout) Tried putting the unit in fan only mode. Still sets code 44. The blower turns freely but does not attempt to start. Tech came out and said I have a bad blower motor. I watched him check the blower then after he left I got the troubleshooting guide out. He did not follow the procedure outlined in the book.
Standard Programming Module. Note: This offer does not include old “card style-TOL01829” programmers. (See Motor Programmer Identification, page 3) The new Pocket Programming Module is capable of programming the new X13 motors. This offer is available only through Regal Beloit Corporation directly and not through ServiceFirst.
X-13 Motor Problems Replacing NTC Thermister? - HVAC-Talk
Sep 18, 2012 · Sometimes the motor will still run with a phase to phase short, just not at full speed, and will make a terrible noise that actually sounds somewhat like a bad bearing. Pop the module off and check the resistance between each motor lead, and each other lead, if all 3 resistance readings are not the same, there is a phase to phase short in the ...
What motor are you guys using to replace the ecm 2.3? - HVAC-Talk
Dec 26, 2018 · Some brands/models require a signal from the motor before they will allow the furnace to fire. With our Rheems, that is the case. Nordyne as well. A-S/Trane do allow a temp motor, done it twice on our furnace at the office. If you have a burnt MOV or whatever that thing is in the module, sometimes you can twist the leads together and get it to ...
Bryant 355MAV codes 41/44 - HVAC-Talk
Nov 21, 2024 · Hey gang I have a Bryant 355 MAV that is giving codes 44 then 41.These are for ECM motor speed issues.The ignition/blower control Has just been replaced,the motor module too.I verified the part numbers are the correct ones.On a call for heat the burners ignite,the ecm blower motor begins ramping up ,once it gets to about half heating speed I would say,burners …
Trane variable speed blower motor, module and board problems
Jan 15, 2015 · probably only needed a new module from the way the problem sounds 100%, with these ecm motors if the static pressure isn't right, you'll burn up the lil caps in module, if you took a pic of module and posted i could help, you could actually get away with twinning the wires left from burnt diode and it will run the newer ecm's have far better ...